Shore Building Energy Assessment · Free · No email required

    Building Window Film Energy Analysis

    Model how window film could change solar heat through a building's glass and the cooling electricity that follows. Enter window groups, rated SHGC values, HVAC efficiency and your energy rate, then print a client-ready report. Results are a preliminary cooling-season scenario from your inputs.

    Single home? Try the window tint energy savings calculator.

    Step 1: Building & windows

    Printed on the report. It does not set climate or weather.

    Context only. Never used as glass area or in the savings math.

    Building photo (optional)

    JPEG, PNG or WebP up to 5 MB. Stays in your browser — never uploaded.

    Window groups

    One group per glass type. Enter actual exposed glass area on the same basis as the SHGC ratings. Different glass needs a separate group.

    Group 1

    Descriptive label — not an energy factor.

    Results unavailable

    • Group 1: glass area is required.
    • Group 1: SHGC before is required.
    • Group 1: SHGC after is required.
    • Electricity rate is required.

    How the building analysis works

    For each window group, reference solar heat = glass area × incident sun on the window plane × SHGC. The difference between existing and after-film SHGC gives the change in solar heat at that reference intensity.

    That change is divided by the cooling system's effective EER to get avoided electrical power at the reference sun intensity (not a measured or billed peak demand), multiplied by equivalent full-sun hours per day, cooling days and a coincidence fraction to get a cooling-season kWh range, then multiplied by your energy-only rate.

    Worked example: 1,000 sq ft of single-pane clear glass

    Using 3M's published Prestige 70 reference values for 1/4-inch single-pane clear glass (SHGC 0.82 before, 0.51 after), 200 BTU/(h·ft²) of sun on the glass, EER 12, $0.20/kWh, 2–4 equivalent hours, 120 days and 0.8 coincidence:

    Reference solar heat falls from 164,000 to 102,000 BTU/h, a 62,000 BTU/h change (about 5.17 tons equivalent). That is 992–1,984 kWh and $198–$397 of avoided cooling electricity in the scenario. The 37.8% is a solar-heat reduction through that glass, not a share of the electric bill.

    Why matched SHGC ratings matter

    SHGC depends on the film and the glass together. A rating published for single-pane clear glass does not describe Low-E or tinted insulated units. Use film-on-glass values published for glass matching yours, or enter custom values with their source. Marketing figures such as infrared rejection or TSER are not SHGC.

    What the analysis does not model

    Heating-season effects, conduction changes, lighting, humidity, HVAC part-load behavior, weather files and demand charges are not modeled, so the result is not annual net savings, peak demand savings, payback or an energy audit. Utility bills you enter are shown as context and a plausibility check only.

    Frequently asked questions

    Is this an energy audit or engineering study?

    No. It is a preliminary cooling-season scenario built from the inputs and assumptions shown. It is not calibrated to your building, hourly weather or metered data, and it is not a licensed engineering analysis.

    Where do the film ratings come from?

    The built-in profiles are 3M's published reference values for Prestige 70 and Prestige 50 (Revision A, April 2019) and Night Vision 15 (Revision B, June 2021), each on four specific glass configurations. For any other film or glass, enter the matching manufacturer film-on-glass SHGC values and note the source.

    Can I enter my building's whole electric bill?

    You can enter annual or monthly electricity use and spend as context. The tool never treats the whole bill as cooling cost; it only checks whether the modeled cooling kWh looks plausible next to a full year of data.

    What EER should I use?

    Use the effective EER (or EER2) of the cooling system, not SEER. For chilled-water plants, use an effective whole-system value including auxiliary power. A COP converts to EER by multiplying by 3.412.

    Does system tonnage change the savings?

    No. Tonnage is optional and only compares the reference heat change with installed capacity. It does not mean equipment can be downsized.

    Does it calculate payback or annual savings?

    No. Because heating effects and demand charges are not modeled, the tool reports a cooling-season range only and does not compute ROI or payback.

    Shore Tint & More
    Shore Tint & More, Inc.
    (302) 947-4624 · info@shoretintandmore.com
    DelawareWindowFilm.com

    Preliminary assessment — inputs and assumptions shown

    Shore Building Energy Assessment

    Unnamed project · November 6, 2026

    Executive summary

    The scenario is incomplete. Enter the glass area and matching SHGC ratings for each window group, the effective EER and an energy-only electricity rate to see results.

    Proposed windowsGroup 1: — ft², film not entered
    Cooling-season rangeUnavailable — inputs incomplete

    Heating effects and demand charges aren't modeled. Not annual net savings, an audit, payback or a licensed engineering analysis.

    Appendix A — Window groups and film ratings

    GroupElevationArea ft²FilmSHGC before→afterProvenance / sourceSolar heat BTU/h
    Group 1—not entered—? → ?Not enteredunavailable

    Appendix B — HVAC and operating assumptions

    Reference sun on window plane, BTU/(h·ft²)200Illustrative assumption
    Effective cooling EER12Illustrative assumption
    Energy-only rate, $/kWhnot entered
    Lower equivalent full-sun hours/day2Illustrative assumption
    Upper equivalent full-sun hours/day4Illustrative assumption
    Cooling-season days120Illustrative assumption
    Cooling coincidence fraction (0–1)0.8Illustrative assumption
    Installed cooling capacity, tons (optional)not entered

    Reference sun intensity applied uniformly to all groups. Floor area not entered ft² (context only).

    Unavailable: Group 1: glass area is required. Group 1: SHGC before is required. Group 1: SHGC after is required. Electricity rate is required.

    Appendix C — Utility data (context)

    Annual kWh: not entered · Annual spend: not entered · Monthly kWh: entered 0 months · Monthly spend: entered 0 months

    Annual kWh coverage: partial — entered 0 of 12 months (not an annual total). Annual spend coverage: partial — entered 0 of 12 months (not an annual total).

    MonthkWhSpend $
    Jannot enterednot entered
    Febnot enterednot entered
    Marnot enterednot entered
    Aprnot enterednot entered
    Maynot enterednot entered
    Junnot enterednot entered
    Julnot enterednot entered
    Augnot enterednot entered
    Sepnot enterednot entered
    Octnot enterednot entered
    Novnot enterednot entered
    Decnot enterednot entered

    Method, limitations and sources

    How the building analysis works. For each window group, reference solar heat = glass area × incident sun on the window plane × SHGC. The difference between existing and after-film SHGC gives the change in solar heat at that reference intensity. That change is divided by the cooling system's effective EER to get avoided electrical power at the reference sun intensity (not a measured or billed peak demand), multiplied by equivalent full-sun hours per day, cooling days and a coincidence fraction to get a cooling-season kWh range, then multiplied by your energy-only rate.

    Why matched SHGC ratings matter. SHGC depends on the film and the glass together. A rating published for single-pane clear glass does not describe Low-E or tinted insulated units. Use film-on-glass values published for glass matching yours, or enter custom values with their source. Marketing figures such as infrared rejection or TSER are not SHGC.

    What the analysis does not model. Heating-season effects, conduction changes, lighting, humidity, HVAC part-load behavior, weather files and demand charges are not modeled, so the result is not annual net savings, peak demand savings, payback or an energy audit. Utility bills you enter are shown as context and a plausibility check only.

    • 3M Sun Control Window Film Technical Data Sheet — Prestige 70 (Rev. A, April 2019) — https://multimedia.3m.com/mws/media/1705623O/prestige-70.pdf
    • 3M Sun Control Window Film Technical Data Sheet — Prestige 50 (Rev. A, April 2019) — https://multimedia.3m.com/mws/media/1705619O/prestige-50.pdf
    • 3M Sun Control Window Film Technical Data Sheet — Night Vision 15 (Rev. B, June 2021) — https://multimedia.3m.com/mws/media/1705625O/tehnical-data-sheet-night-vision-15-vlt.pdf
    • U.S. DOE Building America — Measure Guideline: Windows — https://www1.eere.energy.gov/buildings/publications/pdfs/building_america/measure_guide_windows.pdf
    • U.S. DOE Building America — Energy Renovations HVAC Guide (EER) — https://doi.org/10.2172/1067974