Building Window Film Energy Analysis
Model how window film could change solar heat through a building's glass and the cooling electricity that follows. Enter window groups, rated SHGC values, HVAC efficiency and your energy rate, then print a client-ready report. Results are a preliminary cooling-season scenario from your inputs.
Single home? Try the window tint energy savings calculator.
Step 1: Building & windows
Printed on the report. It does not set climate or weather.
Context only. Never used as glass area or in the savings math.
Building photo (optional)
Window groups
One group per glass type. Enter actual exposed glass area on the same basis as the SHGC ratings. Different glass needs a separate group.
Results unavailable
- Group 1: glass area is required.
- Group 1: SHGC before is required.
- Group 1: SHGC after is required.
- Electricity rate is required.
How the building analysis works
For each window group, reference solar heat = glass area × incident sun on the window plane × SHGC. The difference between existing and after-film SHGC gives the change in solar heat at that reference intensity.
That change is divided by the cooling system's effective EER to get avoided electrical power at the reference sun intensity (not a measured or billed peak demand), multiplied by equivalent full-sun hours per day, cooling days and a coincidence fraction to get a cooling-season kWh range, then multiplied by your energy-only rate.
Worked example: 1,000 sq ft of single-pane clear glass
Using 3M's published Prestige 70 reference values for 1/4-inch single-pane clear glass (SHGC 0.82 before, 0.51 after), 200 BTU/(h·ft²) of sun on the glass, EER 12, $0.20/kWh, 2–4 equivalent hours, 120 days and 0.8 coincidence:
Reference solar heat falls from 164,000 to 102,000 BTU/h, a 62,000 BTU/h change (about 5.17 tons equivalent). That is 992–1,984 kWh and $198–$397 of avoided cooling electricity in the scenario. The 37.8% is a solar-heat reduction through that glass, not a share of the electric bill.
Why matched SHGC ratings matter
SHGC depends on the film and the glass together. A rating published for single-pane clear glass does not describe Low-E or tinted insulated units. Use film-on-glass values published for glass matching yours, or enter custom values with their source. Marketing figures such as infrared rejection or TSER are not SHGC.
What the analysis does not model
Heating-season effects, conduction changes, lighting, humidity, HVAC part-load behavior, weather files and demand charges are not modeled, so the result is not annual net savings, peak demand savings, payback or an energy audit. Utility bills you enter are shown as context and a plausibility check only.
Frequently asked questions
Is this an energy audit or engineering study?
No. It is a preliminary cooling-season scenario built from the inputs and assumptions shown. It is not calibrated to your building, hourly weather or metered data, and it is not a licensed engineering analysis.
Where do the film ratings come from?
The built-in profiles are 3M's published reference values for Prestige 70 and Prestige 50 (Revision A, April 2019) and Night Vision 15 (Revision B, June 2021), each on four specific glass configurations. For any other film or glass, enter the matching manufacturer film-on-glass SHGC values and note the source.
Can I enter my building's whole electric bill?
You can enter annual or monthly electricity use and spend as context. The tool never treats the whole bill as cooling cost; it only checks whether the modeled cooling kWh looks plausible next to a full year of data.
What EER should I use?
Use the effective EER (or EER2) of the cooling system, not SEER. For chilled-water plants, use an effective whole-system value including auxiliary power. A COP converts to EER by multiplying by 3.412.
Does system tonnage change the savings?
No. Tonnage is optional and only compares the reference heat change with installed capacity. It does not mean equipment can be downsized.
Does it calculate payback or annual savings?
No. Because heating effects and demand charges are not modeled, the tool reports a cooling-season range only and does not compute ROI or payback.
Sources
- 3M Sun Control Window Film Technical Data Sheet — Prestige 70 (Rev. A, April 2019)
- 3M Sun Control Window Film Technical Data Sheet — Prestige 50 (Rev. A, April 2019)
- 3M Sun Control Window Film Technical Data Sheet — Night Vision 15 (Rev. B, June 2021)
- U.S. DOE Building America — Measure Guideline: Windows
- U.S. DOE Building America — Energy Renovations HVAC Guide (EER)
Related: commercial energy-efficiency film · 3M commercial window film · architect & GC resources
Created by Shore Tint & More, Inc. · Last updated October 2, 2026 · (302) 947-4624

(302) 947-4624 · info@shoretintandmore.com
DelawareWindowFilm.com
Preliminary assessment — inputs and assumptions shown
Shore Building Energy Assessment
Unnamed project · November 6, 2026
Executive summary
The scenario is incomplete. Enter the glass area and matching SHGC ratings for each window group, the effective EER and an energy-only electricity rate to see results.
| Proposed windows | Group 1: — ft², film not entered |
| Cooling-season range | Unavailable — inputs incomplete |
Heating effects and demand charges aren't modeled. Not annual net savings, an audit, payback or a licensed engineering analysis.
Appendix A — Window groups and film ratings
| Group | Elevation | Area ft² | Film | SHGC before→after | Provenance / source | Solar heat BTU/h |
|---|---|---|---|---|---|---|
| Group 1 | — | not entered | — | ? → ? | Not entered | unavailable |
Appendix B — HVAC and operating assumptions
| Reference sun on window plane, BTU/(h·ft²) | 200 | Illustrative assumption |
| Effective cooling EER | 12 | Illustrative assumption |
| Energy-only rate, $/kWh | not entered | |
| Lower equivalent full-sun hours/day | 2 | Illustrative assumption |
| Upper equivalent full-sun hours/day | 4 | Illustrative assumption |
| Cooling-season days | 120 | Illustrative assumption |
| Cooling coincidence fraction (0–1) | 0.8 | Illustrative assumption |
| Installed cooling capacity, tons (optional) | not entered |
Reference sun intensity applied uniformly to all groups. Floor area not entered ft² (context only).
Unavailable: Group 1: glass area is required. Group 1: SHGC before is required. Group 1: SHGC after is required. Electricity rate is required.
Appendix C — Utility data (context)
Annual kWh: not entered · Annual spend: not entered · Monthly kWh: entered 0 months · Monthly spend: entered 0 months
Annual kWh coverage: partial — entered 0 of 12 months (not an annual total). Annual spend coverage: partial — entered 0 of 12 months (not an annual total).
| Month | kWh | Spend $ |
|---|---|---|
| Jan | not entered | not entered |
| Feb | not entered | not entered |
| Mar | not entered | not entered |
| Apr | not entered | not entered |
| May | not entered | not entered |
| Jun | not entered | not entered |
| Jul | not entered | not entered |
| Aug | not entered | not entered |
| Sep | not entered | not entered |
| Oct | not entered | not entered |
| Nov | not entered | not entered |
| Dec | not entered | not entered |
Method, limitations and sources
How the building analysis works. For each window group, reference solar heat = glass area × incident sun on the window plane × SHGC. The difference between existing and after-film SHGC gives the change in solar heat at that reference intensity. That change is divided by the cooling system's effective EER to get avoided electrical power at the reference sun intensity (not a measured or billed peak demand), multiplied by equivalent full-sun hours per day, cooling days and a coincidence fraction to get a cooling-season kWh range, then multiplied by your energy-only rate.
Why matched SHGC ratings matter. SHGC depends on the film and the glass together. A rating published for single-pane clear glass does not describe Low-E or tinted insulated units. Use film-on-glass values published for glass matching yours, or enter custom values with their source. Marketing figures such as infrared rejection or TSER are not SHGC.
What the analysis does not model. Heating-season effects, conduction changes, lighting, humidity, HVAC part-load behavior, weather files and demand charges are not modeled, so the result is not annual net savings, peak demand savings, payback or an energy audit. Utility bills you enter are shown as context and a plausibility check only.
- 3M Sun Control Window Film Technical Data Sheet — Prestige 70 (Rev. A, April 2019) — https://multimedia.3m.com/mws/media/1705623O/prestige-70.pdf
- 3M Sun Control Window Film Technical Data Sheet — Prestige 50 (Rev. A, April 2019) — https://multimedia.3m.com/mws/media/1705619O/prestige-50.pdf
- 3M Sun Control Window Film Technical Data Sheet — Night Vision 15 (Rev. B, June 2021) — https://multimedia.3m.com/mws/media/1705625O/tehnical-data-sheet-night-vision-15-vlt.pdf
- U.S. DOE Building America — Measure Guideline: Windows — https://www1.eere.energy.gov/buildings/publications/pdfs/building_america/measure_guide_windows.pdf
- U.S. DOE Building America — Energy Renovations HVAC Guide (EER) — https://doi.org/10.2172/1067974